New Sample Preparation and Introduction Systems for Isotope Analysis by Plasma Mass Spectrometry
Requirements 1) Automated ion exchange chromatography system A completely automated system for separating and collecting elements of interest from complex sample matrices via low pressure chromatography. The system should automate acid washes, column conditioning, sample loading, and elution, while allowing for collection of multiple fractions. The model should have the flexibility to change the chemistry of the automated protocol to focus on different elements as well. Specifically we are interested in small volum...
Buyer
University of St Andrews
Value
£41,040
Published
27 Jan 2021
Closes
14 Dec 2020
Procurement details
Source
Pcs
Region
UKM72
Procurement method
Open
Category
Goods
Contract starts
Not provided
Contract ends
Not provided
CPV classifications
38400000
Instruments for checking physical characteristics
Lots
Lot 2 Sample introduction system for ICPMS
£17,071
A desolvating nebulizer introduction system for ICPMS isotope measurements. It should be able to withstand trace HF acid and be flexibly used for multiple isotopic systems (any contamination can be efficiently cleaned away).
Delivery: UKM72
Lot 1 Automated ion exchange chromatography system
£41,040
Requirements 1) Automated ion exchange chromatography system A completely automated system for separating and collecting elements of interest from complex sample matrices via low pressure chromatography. The system should automate acid washes, column conditioning, sample loading, and elution, while allowing for collection of multiple fractions. The model sho...
Delivery: UKM72
Documents
Unlock document linkNew Sample Preparation and Introduction Systems for Isotope Analysis by Plasma Mass Spectrometry
Not provided
Requirements 1) Automated ion exchange chromatography system A completely automated system for separating and collecting elements of interest from complex sample matrices via low pressure chromatography. The system should automate acid wash...
Contract notice · Web page
Portal Instructions
23 Nov 2020
New Sample Preparation and Introduction Systems for Isotope Analysis by Plasma Mass Spectrometry
Not provided
Requirements 1) Automated ion exchange chromatography system A completely automated system for separating and collecting elements of interest from complex sample matrices via low pressure chromatography. The system should automate acid wash...
Award notice · Web page
Contains public sector information licensed under the Open Government Licence v3.0.