3" Cryogenic Valve
HSE require a 3" cryogenic valve for an experimental programme. The valve must be suitable for liquid hydrogen service (down to 20 K) and have pneumatic actuation (open/closed). The valve should have a position indicator rated for ATEX Zone 1. The valve should have flanged connections (ANSI class 300). The valve should have a maximum allowable working pressure of 40 barg. Nominal process conditions: Hydrogen, 50 - 70 K, 0 - 1.5 kg/s, 0 -12 barg The equipment is required for use at the HSE Buxton (SK17 9JN) test sit...
Buyer
Health and Safety Executive
Value
£18,000
Published
5 Jan 2026
Closes
2 Feb 2026
Procurement details
Source
Find a Tender
Region
Sefton
Procurement method
Open
Category
Goods
Contract starts
Not provided
Contract ends
Not provided
CPV classifications
38810000
Industrial process control equipment
44162000
Piping
Lots
Lot 1 3" Cryogenic Valve
£18,000
Delivery: UK · United Kingdom
Documents
Unlock document linkPlanned procurement notice on Find a Tender
5 Jan 2026
Planned procurement notice on Find a Tender
Planned procurement notice · UK3 · Web page
Contains public sector information licensed under the Open Government Licence v3.0.