Pipeline Noticeocds-h6vhtk-05ff17

3" Cryogenic Hydrogen Vent Stack with Changeable Terminations

HSE require a 3" vent stack for use with cryogenic hydrogen for an experimental programme. The vent must have interchangeable terminations (miter cut, bullhorn) which may be on a flanged connection or otherwise joined. The vent stack (including the termination) should have a height of 7 m and the vent stack must have a maximum allowable working pressure of 40 barg. Nominal process conditions: Hydrogen, 50 - 70 K, 0 - 1.5 kg/s, 0 -12 barg The equipment is required for use at the HSE Buxton (SK17 9JN) test site. HSE...

Buyer

Health and Safety Executive

Value

£25,000

Published

5 Jan 2026

Closes

2 Feb 2026

Procurement details

Source

Find a Tender

Region

Sefton

Procurement method

Open

Category

Goods

Contract starts

Not provided

Contract ends

Not provided

CPV classifications

38810000

Industrial process control equipment

44162000

Piping

Lots

Lot 1 3" Cryogenic Hydrogen Vent Stack with Changeable Terminations

£25,000

Delivery: UK · United Kingdom

Planned procurement notice on Find a Tender

5 Jan 2026

Planned procurement notice on Find a Tender

Planned procurement notice · UK3 · Web page

Contains public sector information licensed under the Open Government Licence v3.0.