Horizontally Deflecting Double Crystal Monochromator for Beamline VMXm
The specification details the requirements for the design, manufacture, supply and installation of a horizontallydeflecting Double Crystal Monochromator (DCM) for use at DLS. The monochromator system should include liquid nitrogen cryogenic cooling and one crystal set. All motors,encoders and limits should be included. The tender document gives detailed technical specifications for the DCM system, guided by the properties of thesource and an assessment of available technology. If the required performance can be met...
Buyer
Diamond Light Source Ltd
Value
£202,239
Published
18 Nov 2016
Closes
11 Feb 2015
Procurement details
Source
Contracts Finder
Region
United Kingdom
Procurement method
Open
Category
Goods
Contract starts
27 Mar 2015
Contract ends
13 Jun 2016
CPV classifications
33111000
X-ray devices
Lots
Lot default Horizontally Deflecting Double Crystal Monochromator for Beamline VMXm
£202,239
The specification details the requirements for the design, manufacture, supply and installation of a horizontallydeflecting Double Crystal Monochromator (DCM) for use at DLS. The monochromator system should include liquid nitrogen cryogenic cooling and one crystal set. All motors,encoders and limits should be included. The tender document gives detailed tech...
Delivery: South East · United Kingdom, South East, United Kingdom
Documents
Unlock document linkAwarded contract notice on Contracts Finder
6 May 2015
Awarded contract notice on Contracts Finder
Award notice · Web page
Contains public sector information licensed under the Open Government Licence v3.0.